Configuring PPPoA.
1. Select PPPoA as profile type and
click on OK.
2. Set Authentication.
Fill in your Username and Password.
Choose the Authentication
Protocol.(PAP or CHAP)
Set the LAN TCP/IP parameters.
(CopperJet 81x IP-Address)
The Default Gateway of your local
network will be the CopperJet 81x
IP-Address
Set the interface type.
USB when the CopperJet 81x is
connected with a USB cable.
Ethernet when the CopperJet 81x
is connected with a Ethernet
cable.
Select the Line modulation.(ADSL connection Protocol)
-Multimode : Modem will detect the Modulation offered by the CO (Preferred)
-T1.413 : ANSI ADSL Standard
-G.Lite : G.992.2
-G.Dmt : G.992.1 Annex A
Set the ATM PVC (Virtual Circuit) parameters.
-VPI :VPI Channel Number
-VCI :VCI Channel Number